office (636) 366-9200
fax (636) 356-1237

Properties of Saturated Steam

 

PSIG

KG/CM2

Fo

Co

Total BTU P/Lb. Steam Pick Heater

Heat of Condensate / Lb.

Latent or Usable
 Heat / Lb.  Heat Exchanger

0

0.00

212

100

1150

180

970

5

0.35

228

109

1156

196

960

10

0.70

240

116

1160

208

952

15

1.05

250

121

1164

218

946

20

1.41

259

126

1167

228

939

25

1.76

267

131

1169

236

933

35

2.46

281

138

1174

250

924

50

3.52

297

147

1178

267

911

60

4.22

307

153

1181

277

904

70

4.92

316

158

1183

286

897

80

5.62

324

162

1186

294

892

90

6.33

331

166

1187

302

885

100

7.03

338

170

1189

309

880

125

8.79

353

178

1193

324

869

150

10.55

366

186

1195

338

857

175

12.30

377

192

1197

350

847

200

14.00

387

197

1198

355

843

225

15.82

395

202

1200

372

828

250

17.58

406

208

1201

380

821

275

19.33

414

212

1202

387

815

300

21.08

420

216

1203

400

803

350

24.60

435

224

1204

412

792

400

28.12

448

231

1204

429

775

450

31.64

460

238

1204

439

765

500

35.15

470

243

1208

449

759